SIEMENS SINAMICS S120 45A Booksize Single Motor Module

Availability: Approx 6 weeks

£3,090.35 Plus VAT and Shipping

SINAMICS S120 SINGLE MOTOR MODULE INPUT: DC 600V OUTPUT: 3AC 400V, 45A FRAME SIZE: BOOKSIZE INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE AND SUPPORT OF THE EXTENDED SAFETY INTEGRATED FUNCTIONS INCL. DRIVE-CLIQ CABLE

 

Description

Manufacturer: Siemens

Range: SINAMICS S120 Booksize

Model: 6SL3120-1TE24-5AA3

Rated data
DC link voltage DC 510 ... 720 V
Electronics power supply DC 24 V -15 % / +20 %
Current demand, max. 1.20 A
DC-link current Id 54.0 A
Output current
Rated value IN 45.0 A
Base load current IH 38.0 A
For S6 duty (40%) IS6 60.0 A
Imax 85.0 A
Type rating 2)
Based on IN 24.0 kW
Based on IH 21.0 kW
Rated pulse frequency 4.00 kHz
Current carrying capacity
DC link busbars 200 A
24 V busbars 20 A
DC link capacitance 1175 µF
Output frequency for servo control 5) 650 Hz
Output frequency for V/f control 6) 600 Hz
Output frequency for vector control 7) 300 Hz
Mechanical data
Line side
Width 150.00 mm (5.91 in)
Height 380.00 mm (14.96 in)
Depth 270.00 mm (10.63 in)
Degree of protection IP20 / UL open type
Type of construction Booksize
Net weight 9.0 kg (19.84 lb)
Ambient Conditions
Installation altitude (without derating) 1000 m (3281 ft)
Cooling 8) Internal air cooling
Cooling air requirement 0.031 m³/s
Ambient temperature
During operation 0 ... 40 °C (32 ... 104 °F)
Connections
Motor end
Version M6 bolt (X1)
Conductor cross-section 3 ... 50 mm² (14 ... 1 AWG)
PE connection M6 screw
Max. motor cable length
Shielded 100 m (328 ft)
Unshielded 150 m (492 ft)
Standards
Compliance with standards CE, cULus
Safety Integrated SIL 2 acc. to IEC 61508, PL d acc. to EN ISO 13849-1, Category 3 acc. to EN ISO 13849-1
General tech. specifications
Sound pressure level (1m) 65.0 dB
Power loss, typ./max. 9) 0.38 kW / 0.46 kW

 

Notes:

1) Rated dc link current for dimensioning an external DC connection

2) Rated output of a typical standard asynchronous motor at 400 V 3 AC

3) 200 A possible with reinforced DC link bridges (accessory).

4) If, when connecting several Line Modules and Motor Modules in series, the current carrying capacity exceeds 20 A, another 24 V DC connection is required using a 24 V terminal adapter (max. connectable cross-section 6 mm2, max. protection 20 A).

5) With rated output current (max. output frequency 1300 Hz at a current controller cycle of 62.5 µs, pulse frequency 8 kHz, 60 % permissible output current). Observe the dependency between max. output frequency and current derating. At present, the output frequency is limited to 550 Hz, the values stated apply with the high output frequency license.

6) Observe the dependency between max. output frequency and current derating. At present, the output frequency is limited to 550 Hz, the values stated apply with the high output frequency license.

7) Observe the dependency between max. output frequency and current derating.

8) Power units with intensified air cooling thanks to integrated fan.

9) Power loss of the Motor Module with rated power including losses of the 24 V DC electronics power supply