M200 Quick Reference Selection Guide
M200 delivers an economical open loop drive for general Manufacturing Automation applications, with Control Techniques’ proven quality and class leading motor operation.
Unidrive M200 benefits include:
Quick and easy to install and configure
Reduce machine size and cost
Save energy
Robust design for manufacturing and environments
[table id=1 /]
400V Inverters
<table id=”tablepress-1″ class=”tablepress tablepress-id-1″>
<thead>
<tr class=”row-1 odd”>
<th class=”column-1″>Part Number</th>
<th class=”column-2″>Input Phases</th>
<th class=”column-3″>Power (kW)</th>
<th class=”column-4″>Current (A)</th>
<th class=”column-5″>Frame size</th>
<th class=”column-6″>Dimensions (mm)
(H x W x D)</th>
</tr>
</thead>
<tbody class=”row-hover”>
<tr class=”row-2 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-0-37kw-hd-1-3amp-380v-480v-ac-drive/”>M200-02400013</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>0.37</td>
<td class=”column-4″>1.3</td>
<td class=”column-5″>2</td>
<td class=”column-6″>205mm(H) x 75mm(W) x 150mm(D)</td>
</tr>
<tr class=”row-3 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-0-55kw-hd-1-8amp-380v-480v-ac-drive/”>M200-02400018</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>0.55</td>
<td class=”column-4″>1.8</td>
<td class=”column-5″>2</td>
<td class=”column-6″>205mm(H) x 75mm(W) x 150mm(D)</td>
</tr>
<tr class=”row-4 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-0-75kw-hd-2-3amp-380v-480v-ac-drive/”>M200-02400023</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>0.75</td>
<td class=”column-4″>2.3</td>
<td class=”column-5″>2</td>
<td class=”column-6″>205mm(H) x 75mm(W) x 150mm(D)</td>
</tr>
<tr class=”row-5 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-1-1kw-hd-3-2amp-380v-480v-ac-drive/”>M200-02400032</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>1.1</td>
<td class=”column-4″>3.2</td>
<td class=”column-5″>2</td>
<td class=”column-6″>205mm(H) x 75mm(W) x 150mm(D)</td>
</tr>
<tr class=”row-6 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-1-5kw-hd-4-1amp-380v-480v-ac-drive/”>M200-02400041</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>1.5</td>
<td class=”column-4″>4.1</td>
<td class=”column-5″>2</td>
<td class=”column-6″>205mm(H) x 75mm(W) x 150mm(D)</td>
</tr>
<tr class=”row-7 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-2-2kw-hd-5-6amp-380v-480v-ac-drive/”>M200-03400056</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>2.2</td>
<td class=”column-4″>5.6</td>
<td class=”column-5″>3</td>
<td class=”column-6″>226mm(H) x 90mm(W) x 160mm(D)</td>
</tr>
<tr class=”row-8 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-3kw-hd-7-3amp-380v-480v-ac-drive/”>M200-03400073</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>3</td>
<td class=”column-4″>7.3</td>
<td class=”column-5″>3</td>
<td class=”column-6″>226mm(H) x 90mm(W) x 160mm(D)</td>
</tr>
<tr class=”row-9 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-4kw-hd-9-4amp-380v-480v-ac-drive/”>M200-03400095</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>4</td>
<td class=”column-4″>9.4</td>
<td class=”column-5″>3</td>
<td class=”column-6″>226mm(H) x 90mm(W) x 160mm(D)</td>
</tr>
<tr class=”row-10 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-5-5kw-hd-13-5amp-380v-480v-ac-drive/”>M200-04400135</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>5.5</td>
<td class=”column-4″>13.5</td>
<td class=”column-5″>4</td>
<td class=”column-6″>277mm(H) x 115mm(W) x 175mm(D)</td>
</tr>
<tr class=”row-11 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-7-5kw-hd-17amp-380v-480v-ac-drive/”>M200-04400170</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>7.5</td>
<td class=”column-4″>17</td>
<td class=”column-5″>4</td>
<td class=”column-6″>277mm(H) x 115mm(W) x 175mm(D)</td>
</tr>
<tr class=”row-12 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-11kw-hd-27amp-380v-480v-ac-drive/”>M200-05400270</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>11</td>
<td class=”column-4″>27</td>
<td class=”column-5″>5</td>
<td class=”column-6″>391mm(H) x 143mm(W) x 192mm(D)</td>
</tr>
<tr class=”row-13 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-15kw-hd-30amp-380v-480v-ac-drive/”>M200-05400300</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>15</td>
<td class=”column-4″>30</td>
<td class=”column-5″>5</td>
<td class=”column-6″>391mm(H) x 143mm(W) x 192mm(D)</td>
</tr>
<tr class=”row-14 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-15kw-hd-35amp-380v-480v-ac-drive/”>M200-06400350</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>15</td>
<td class=”column-4″>35</td>
<td class=”column-5″>6</td>
<td class=”column-6″>391mm(H) x 210mm(W) x 221mm(D)</td>
</tr>
<tr class=”row-15 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-18-5kw-hd-42amp-380v-480v-ac-drive/”>M200-06400420</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>18.5</td>
<td class=”column-4″>42</td>
<td class=”column-5″>6</td>
<td class=”column-6″>391mm(H) x 210mm(W) x 221mm(D)</td>
</tr>
<tr class=”row-16 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-22kw-hd-47amp-380v-480v-ac-drive/”>M200-06400470</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>22</td>
<td class=”column-4″>47</td>
<td class=”column-5″>6</td>
<td class=”column-6″>391mm(H) x 210mm(W) x 221mm(D)</td>
</tr>
<tr class=”row-17 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-37kw-hd-77amp-380v-480v-ac-drive/”>M200-07400660</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>30</td>
<td class=”column-4″>66</td>
<td class=”column-5″>7</td>
<td class=”column-6″>557mm(H) x 270mm(W) x 280mm(D)</td>
</tr>
<tr class=”row-18 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-37kw-hd-77amp-380v-480v-ac-drive/”>M200-07400770</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>37</td>
<td class=”column-4″>77</td>
<td class=”column-5″>7</td>
<td class=”column-6″>557mm(H) x 270mm(W) x 280mm(D)</td>
</tr>
<tr class=”row-19 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-45kw-hd-100amp-380v-480v-ac-drive/”>M200-07401000</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>45</td>
<td class=”column-4″>100</td>
<td class=”column-5″>7</td>
<td class=”column-6″>557mm(H) x 270mm(W) x 280mm(D)</td>
</tr>
<tr class=”row-20 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-55kw-hd-134amp-380v-480v-ac-drive/”>M200-08401340</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>55</td>
<td class=”column-4″>134</td>
<td class=”column-5″>8</td>
<td class=”column-6″>803mm(H) x 310mm(W) x 290mm(D)</td>
</tr>
<tr class=”row-21 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-75kw-hd-157amp-380v-480v-ac-drive/”>M200-08401570</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>75</td>
<td class=”column-4″>157</td>
<td class=”column-5″>8</td>
<td class=”column-6″>803mm(H) x 310mm(W) x 290mm(D)</td>
</tr>
<tr class=”row-22 even”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m200-90kw-hd-200amp-380v-480v-ac-drive/”>M200-09402000</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>90</td>
<td class=”column-4″>200</td>
<td class=”column-5″>9</td>
<td class=”column-6″>1108mm(H) x 310mm(W) x 290mm(D)</td>
</tr>
<tr class=”row-23 odd”>
<td class=”column-1″><a href=”https://www.drivesandautomation.com/product/nidec-control-techniques-unidrive-m700-110kw-hd-224amp-380v-480v-ac-drive/”>M200-09402240</a></td>
<td class=”column-2″>Three</td>
<td class=”column-3″>110</td>
<td class=”column-4″>224</td>
<td class=”column-5″>9</td>
<td class=”column-6″>1108mm(H) x 310mm(W) x 290mm(D)</td>
</tr>
</tbody>
</table>