Description
Ratings & Dimensions
PL 2 Quadrant | KW @ 460v | HP @ 460v | Armature Current DC Amps | Field Amps |
---|---|---|---|---|
PL 185 | 185 | 250 | 430 | 32 |
Dimensions & Shipping info
Height | Width | Depth | Weight |
---|---|---|---|
504mm | 216mm | 315mm | 24kg |
PROTECTION
β Interline device networks
β High energy MOVβs
β Instantaneous over-current
β Field failure and over-current
β Motor over-temperature
β Thyristor stack
β over-temperature
β Mains supply phase loss
β Mains synchronisation loss
β Armature over-volts
β Speed feedback failure
β Stall protection
β Standstill logic
β Thyristor βtriggerβ failure
β Digital output short circuit
INPUTS/OUTPUTS
ANALOGUE INPUTS
β 8 total (resolution 2.5mV+sign)
β All configurable
β All have programmable thresholds and 4 voltage ranges
β +/- 5/10/20/30V
β All inputs are over voltage protected and can also be utilised as digital inputs ANALOGUEΒ OUTPUTS
β 4 Total (resolution 2.5mV+sign)
β 1 armature current output
β 3 configurable
β All outputs are short circuit protected
DIGITAL INPUTS
β 17 total
β All configurable
DIGITAL OUTPUTS
β 7 Total (24V logic 350mA total)
β Short circuit protected
β Over temp and
β over voltage protected
β All configurable
STANDARD SOFTWARE FUNCTIONS
β Full suite of centre winding macros
β Motorised pot simulator with memory
β 2x PIDs (undedicated)
β 2x Summers (undedicated)
β 2x Filters (undedicated)
β Delay timer
β Current Profiling
β Spindle Orientation
β Jog/Crawl functions
β Dual motor swap
β Latch
β Linear or S ramp
β Slack take up
β Batch counter
β Draw control
β Auto self-tune current loop
β 3 user programmable drive configurations
ALARM STATUS
β First fault latched and automatically displayed
β Fault automatically saved at power off MONITORING
β All analogue input voltages
β All digital input states
β All analogue output voltages
β All digital output states
β Tachogenerator voltage
β Motor armature current (amps)
β Motor field current (amps)
β Motor armature volts
β Output power
β AC supply volts
FIELD CONFIGURATIONS
β Fixed current
β Fixed voltage
β Field weakening
β Delayed quenching
β Standby field value
β Field economy ENVIRONMENT
β Ambient operating temperature
β 0-40 ΜC (2050A 2250A 35Β°C)
β 25 to +55 ΜC storage οΏΌ
STEADY STATE ACCURACY
β 0.01% Encoder feedback with digital reference
β 0.1% Analogue tachogenerator feedback
β 2% Armature voltage feedback
β 0.01% Encoder + tach, encoder + AVF or encoder only feedback
β Maximum encoder frequency 100KHz
STANDARDS
CE marked to EN50178 β (low voltage directive)
EN50082-2:1995 β Immunity industrial environment
EN50082-1:1997 β Immunity residential commercial and light industry
EN50081-2:1993 β Emissions industrial environment (EN55011 Class A)
EN50081-1:1992 β Emissions industrial environment (EN55022 Class B)
β UL and cUL listed 12-630Amps
β UL and cUL pending 650-2250Amps