SIEMENS SINAMICS S120 3A Booksize D-Type Single Motor Module

Availability: Approx 6 weeks

£784.25 Plus VAT and Shipping

SINAMICS S120 SINGLE MOTOR MODULE INPUT: DC 600V OUTPUT: 3-PH 400V, 3A FRAME SIZE: BOOKSIZE D-TYPE INTERNAL AIR COOLING OPTIMIZED PULSE SAMPLE AND SUPPORT OF THE EXTENDED SAFETY INTEGRATED FUNCTIONS INCL. DRIVE-CLIQ CABLE

Description

Manufacturer: Siemens

Range: SINAMICS S120 Booksize

Model: 6SL3120-1TE13-0AD0

 

Rated data
DC link voltage DC 510 ... 720 V
Electronics power supply DC 24 V -15 % / +20 %
Current demand, max. 0.75 A
DC-link current Id
1)
3.6 A
Output current
Rated value IN 3.0 A
Base load current IH 2.6 A
For S6 duty (40%) IS6 4.0 A
Imax 9.0 A
Type rating 2)
Based on IN 1.6 kW
Based on IH 1.4 kW
Rated pulse frequency 4.00 kHz
Current carrying capacity
DC link busbars 3) 100 A
24 V busbars 4) 20 A
DC link capacitance 110 µF
Output frequency for servo control 5) 650 Hz
Output frequency for V/f control 6) 600 Hz
Output frequency for vector control 7) 300 Hz
Mechanical data
Line side
Width 50.00 mm (1.97 in)
Height 380.00 mm (14.96 in)
Depth 270.00 mm (10.63 in)
Degree of protection IP20 / UL open type
Type of construction Booksize
Net weight 4.6 kg
Ambient conditions
Installation altitude (without derating) 1000 m (3281 ft)
Cooling 8) Internal air cooling
Cooling air requirement 0.009 m³/s
Ambient temperature
During operation 0 ... 40 °C (32 ... 104 °F)
Connections
Motor end
Version connector (X1)
Conductor cross-section 2 ... 6 mm² (16 ... 10 AWG)
PE connection M5 screw
Max. motor cable length
Shielded 50 m (164 ft)
Unshielded 75 m (246 ft)
Standards
Compliance with standards CE, cULus
Safety Integrated SIL 2 acc. to IEC 61508, PL d acc. to
EN ISO 13849-1, Category 3 acc. to
EN ISO 13849-1
General tech. specifications
Sound pressure level (1m) 60.0 dB
Power loss, typ./max. 9) 0.03 kW / 0.05 kW

Notes

1) Rated dc link current for dimensioning an external DC connection

2) Rated output of a typical standard asynchronous motor at 400 V 3 AC

3) 200 A possible with reinforced DC link bridges (accessory).

4) If, when connecting several Line Modules and Motor Modules in series, the current carrying capacity exceeds 20 A, another 24 V DC connection is required using a 24 V
terminal adapter (max. connectable cross-section 6 mm2, max. protection 20 A).

5) With rated output current (max. output frequency 1300 Hz at a current controller cycle of 62.5 μs, pulse frequency 8 kHz, 60 % permissible output current). Observe the
dependency between max. output frequency and current derating. At present, the output frequency is limited to 550 Hz, the values stated apply with the high output frequency
license.

6) Observe the dependency between max. output frequency and current derating. At present, the output frequency is limited to 550 Hz, the values stated apply with the high
output frequency license.

7) Observe the dependency between max. output frequency and current derating.

8) Power units with intensified air cooling thanks to integrated fan

9) Power loss of the Motor Module with rated power including losses of the 24 V DC electronics power supply